The Bacharach HGMSZ (Halogen Gas Monitor Single Zone) is designed for continuous single-point monitoring of CFC, HFC, HCFC, and Halon refrigerant gases. The HGMSZ displays the type of gas being monitored, along with displaying both the current gas level and the peak gas level detected on its front panel LCD. The instrument retains a log of previous readings that can be easily accessed for analysis.
An internal audible alarm and front panel indicators are provided to signal alarm and fault conditions, and relay contacts can be used to trigger external alarm devices in the event of a system fault, or if a leak (small), spill (medium), or evacuation (large) level of gas is detected. The system also includes a 4-20 mA current loop interface that can be connected to remote monitoring equipment.
Features & Benefits |
- Easily complies with ASHRAE 15 requirements with a low-cost investment
- Eliminate false alarms with use of non-dispersive IR source and sample draw system
- Capable of detecting 30 of the most commonly used refrigerants and halogen gases
- Measure all gases up to 10,000 ppm with a sensitivity of 1 ppm
- Monitors a single zone located up to 50 feet from unit
- Logging feature enables 200 gas readings to be stored
- Three gas alarm levels that can be individually set
- Bolt-in, bolt-out internal components so the unit never leaves the wall
- Two-year warranty
|
Specifications |
- Refrigerant Library: R-11, R-12, R-21, R-22, R-23, R-113, R-114, R-123, R-124, R-134a, R-227, R-236FA, R-401a, R-402a, R-402b, R-404a, R-407a, R-407c, R-408a, R-409a, R-410a, R-500, R-502, R-503, R-507, R-508b, H-1211, H-1301, H-2404, N-1230
- Measuring Range: All gases 0 to 10,000 ppm
- Input: Dedicated single zone
- Output Signals: 4 SPDT, 5 Amp, 240 VAC relays; digital display; and a 4—20 mA DC current loop output
- Detector Type: Single pass, non-dispersive infrared
- Sensitivity: All gases 1 ppm
- Accuracy: All gases ±10 ppm from 0 to 100 ppm, ±10% of reading from 100 to 10,000 ppm
- Front Panel Indicators:
- MONITOR ON — Green light ON when the unit is operating normally, or flashing during warm-up
- SYSTEM FAULT — Yellow light ON when there is a system fault
- ALARM — Red light ON when the gas level is above an alarm setting
- Response Time: 9 to 30 seconds, depending on tube length and gas concentration
- Max. Monitoring Distance: Up to 50 feet from measuring point to monitor
- Operating Temperature: 32 to 122°F (0 to 50°C)
- Humidity: 5 to 90% RH, non-condensing
- Altitude Limit: 2000 Meters
- Power: 100—240 VAC, 50/60 Hz, 15 Watts
- Size/Weight: 14"H x 18"W x 4.7"D / 7 lbs
- Certification: UL 61010A-1, CSA 22.2, CE Mark
-
|
Ordering Information |
Part Number |
Description |
3015-4200 |
HGMSZ (Halogen Gas Monitor Single Zone) |
304-2743 |
Sample / Exhaust / Purge Line tubing |
3015-3420 |
|
3015-4121 |
|
3015-4123 |
4—20 mA surge protector |
3015-3069 |
|
120 VAC external visual alarm |
|
3015-3070 |
|
120 VAC external audible alarm |
|
3015-3076 |
|
120 VAC external audible / visual alarm |
|
|
Back to Products |
Authorised Distributor for the Products of:   |
One Stop Electrical Energy Savings System- Air Conditioners, ACPUs, WCPUs, Chillers, Injection Moulding Machines, Blowers/Fans, Fluorescent Light, Street Light, High Bay Light, High-Mast, Pumps, Air Compressors, Power Quality/ Efficient |
Useful Link:
Suruhanjaya Tenaga
http://www.st.gov.my
Pusat Tenaga Malaysia
http://www.ptm.org.my
Tenaga Nasional Berhad
http://www.tnb.com.my
NIOSH
http://www.niosh.com.my
CIDB
http://www.cidb.gov.my |
ENER-SAVE SDN BHD
47A, Jalan Perwira 9, Taman Ungku Tun Aminah, 81300 Skudai, Johor, Malaysia.
Tel: +607-557 2669,
Fax: +607-558 2669
E-Mail: project@ener-save.biz
 |