Tree
Combustion Efficiency & Environmental Analyzer
Homepage

The ECA 450 is ideal for professionals concerned about combustion efficiency, environmental compliance, or both. It enables plant maintenance engineers and managers, industrial boiler/furnace service technicians, energy coordinators, compliance officers, environmental auditors and safety managers ensure that industrial equipment is burning efficiently while environmental regulations are being met.

Unlike any other industrial grade combustion efficiency and environmental analyzer on the market today, the new ECA 450 from Bacharach conducts accurate combustion and emissions tests that will help you meet environmental regulations and ensure your equipment is burning efficiently. The ECA 450 measures Oxygen, Carbon Monoxide, Nitric Oxide, Nitrogen Dioxide and Sulfur Dioxide, as well as combustibles, temperature and draft. It also calculates combustion efficiency, excess air, carbon dioxide, NOx (Nitrogen Oxides) and pollution units.

The ECA takes continuous samplings of furnaces, boilers and other industrial combustion equipment for up to eight hours and generates precise, reliable combustion and environmental measurements and calculations. And it generates this complex data easily — even at selected intervals — enabling plants to make more accurate equipment adjustments and better assess pollution levels. The ECA 450 helps improve overall combustion efficiency, reduce fuel costs, and determine emissions compliance.

 

ECA-450
Product Information

The use of ETV name or logo does not imply approval or certification of this product nor does it make any explicit or implied statements as to product performance.

 

getpdf

Features & Benefits

  • Large, easy-to-read fluorescent display that is visible from wide angles.
  • Battery life of over eight hours.
  • Modular design lets you add sensors as your needs change.
  • Built-in printer and complete data downloading to a PC capability.
  • EPA-ETV test verified performance.
  • Measures and displays O2 and CO in the flue gas, pressure (draft), primary air temperature, and stack temperature.
  • Calculates and displays combustion efficiency, excess air, and CO2.
  • Optionally measures and displays NO, NO2, SO2, HC (methane equivalent combustibles), and CO in the high range of 4,000 to 80,000 ppm).
  • Optionally calculates NOx (the combination of NO and NO2), and calculates CO, SO2, and NOx individually referenced to a user defined Oxygen level of between 0 and 15%.
  • Optionally displays pollution conversions for CO, NO, NO2, and SO2. Pollution conversions include parts per million, pounds of pollutant per million BTU, milligrams of pollutant per cubic meter of gas, and grams of pollutant per gigajoule.
  • Stores over 1000 individual combustion and/or pressure test records, which can later be recalled for viewing or printing.
  • Stored test records can be downloaded to a personal computer and stored as a text file, which can then be opened in a spreadsheet program for analysis.
  • Performs datalogging.

Specifications

Measured Data
Oxygen
0.1 to 20.9%
Carbon Monoxide (hydrogen compensated)
0 to 4,000 ppm
Carbon Monoxide High
4,001 to 80,000 ppm
Nitric Oxide*
0 to 3,500 ppm
Nitrogen Dioxide*
0 to 500 ppm
Sulfur Dioxide*
0 to 4,000 ppm
Combustibles
0 to 5% (application dependent)
Stack Temp.
-4 to 2400°F (-20 to 1315°C)
Primary/Ambient Temp.
-4 to 999°F (-20 to 999°C)
Pressure/Draft
-27.7 to 27.7 inches of Water
Calculated Data
Combustion Efficiency
0.1 to 100.0%
Excess Air
1.0 to 250%
Carbon Dioxide(dry basis)
0 to fuel dependent maximum
NOx
0 to 4,000 ppm
NOx (ref. to %O2)
0 to 17,000 ppm
CO (ref. to %O2)
0 to 99,9999 ppm
NO (ref. to %O2)
0 to 14,900 ppm
NO2 (ref. to %O2)
0 to 2100 ppm
SO2 (ref. to %O2)
0 to 17,000 ppm
Miscellaneous
Power
Universal AC adapter and an internal battery pack. Adapter will accept input voltages from 100 to 240V. Fully charged battery pack provides a minimum of 8 hours of operation
Pumps & Probe
Two pumps are included. The first pump supplies gas sample to the sensors. The second pump supplies fresh air to purge the low-range CO sensor when CO levels exceed 400 ppm. Probe includes a standard probe and hose assembly equipped with a water trap, particulate filter, probe stop, 15 feet of hose, and 12-inch probe tube
Size
13.5"H x 18.5"W x 9"D (342.9 x 467.0 x 228.6 mm)
Weight
25 lbs (11.34 kg)
Warranty
1 year, extended warranty available

* Optional

 

Ordering Information

Part Number
Description
24-7221
Base Unit (O2, CO, Stack Temp., Primary Air Temp., & Draft)
24-7289
Base Unit (O2, CO, Stack Temp., Primary Air Temp., & Draft) w/ wireless hand-held remote**
24-7223
Heavy duty sample conditioning system (EPA-ETV test verified performance). Includes Peltier chiller unit with integral condensate pump, 15 ft heated hose assembly with probe, and built-in temperature controller.
24-7224
Compact sample conditioner/probe assembly. Includes Peltier chiller/probe assembly, built-in filter, condensate pump, and 15 ft hose assembly.
24-0788
O2 Sensor
24-0789
CO (low) Sensor
24-0997
CO (high) Sensor
24-0881
NO Sensor
24-1055
Combustibles Sensor
24-1027
NO2 Sensor
24-0998
SO2 Sensor (requires NO2 option)
24-1124
20 ft Hose Extension
24-3024
24 inch Probe
24-3025
36 inch Probe
07-1644
Filters (package of 3)
24-7059
Calibration Kit (does not include gas)
104-1800
Thermocouple Wand Extension, 5 feet
104-4027
Serial Cable (DB-9M to DB-9F)
24-0980
Printer Paper (5 rolls)
24-8400
NOx Kit with NO/NO2 sensors and compact sample conditioner
24-8401
NOx and SO2 Kit with NO, NO2, and SO2 sensors and compact sample conditioner
 

** The wireless, hand-held remote is recommended for use of up to 300 ft. indoors with normal obstructions and up to 1,000 ft. outdoors.

Back to Top

 

 

Authorised Distributor for the Products of:BacharachEARTH

Company Profile
Products
Energy Savings Systems
One Stop Electrical Energy Savings System- Air Conditioners, ACPUs, WCPUs, Chillers, Injection Moulding Machines, Blowers/Fans, Fluorescent Light, Street Light, High Bay Light, High-Mast, Pumps, Air Compressors, Power Quality/ Efficient
Past Experiences
Case Studies
Contact Us

Useful Link:

Suruhanjaya Tenaga

http://www.st.gov.my

Pusat Tenaga Malaysia

http://www.ptm.org.my

Tenaga Nasional Berhad

http://www.tnb.com.my

NIOSH

http://www.niosh.com.my

CIDB

http://www.cidb.gov.my

ENER-SAVE SDN BHD

47A, Jalan Perwira 9, Taman Ungku Tun Aminah, 81300 Skudai, Johor, Malaysia.

Tel: +607-557 2669,

Fax: +607-558 2669

E-Mail: project@ener-save.biz

Botpic

Powered by: Ener-Save Sdn Bhd Web Master Group | Home | Company Profile |Products|Energy Savings System | Past Experiences | Case Studies | Contact Us |

Copyright © 2009 All Rights Reserved